Application
Nominal sizes
Parts and characteristics
Construction features
Material and surfaces
Standards and guidelines
Maintenance
Nominal sizes | 100 – 400 mm |
Volume flow rate range | 10 – 750 l/s or 36 – 2700 m³/h |
Thermal output | 0.25 – 18 kW |
Maximum hot water temperature | 150 °C |
Maximum water-side operating pressure | 10 bar |
Water-side differential pressure | 0.3 – 12 kPa |
Air-side static differential pressure | 5 – 80 Pa |
Technical data of the heat exchanger
Basic units: TVR, RN and VFC (TEST)
NS | qv | Δpst | PWW 50/40, te = 16 °C | PWW 70/55, te = 16 °C | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
l/s | m³/h | Pa | Φ [kW] | ta [°C] | qm [kg/h] | Δpv [kPa] | Φ [kW] | ta [°C] | qm [kg/h] | Δpv [kPa] | |
100 | 10 | 36 | 5 | 0.25 | 36.1 | 21 | 0.3 | 0.40 | 48.5 | 23 | 0.5 |
100 | 20 | 72 | 10 | 0.38 | 31.3 | 33 | 0.4 | 0.62 | 41.2 | 36 | 0.6 |
100 | 30 | 108 | 15 | 0.47 | 28.8 | 41 | 0.5 | 0.79 | 37.5 | 46 | 0.7 |
100 | 40 | 144 | 25 | 0.55 | 27.2 | 48 | 0.6 | 0.95 | 35.2 | 55 | 0.8 |
100 | 45 | 162 | 30 | 0.58 | 26.5 | 51 | 0.7 | 1.02 | 34.4 | 59 | 1 |
125 | 18 | 65 | 5 | 0.36 | 32 | 31 | 0.3 | 0.58 | 42.2 | 34 | 0.5 |
125 | 35 | 126 | 20 | 0.51 | 27.9 | 44 | 0.5 | 0.87 | 36.2 | 51 | 0.8 |
125 | 50 | 180 | 40 | 0.62 | 26 | 53 | 1 | 1.09 | 33.8 | 64 | 1 |
125 | 65 | 234 | 60 | 0.7 | 24.8 | 61 | 1.2 | 1.3 | 32.3 | 76 | 1.3 |
125 | 75 | 270 | 80 | 0.76 | 24.2 | 66 | 1.5 | 1.44 | 31.6 | 84 | 1.5 |
160 | 28 | 101 | 5 | 0.69 | 36.1 | 60 | 1 | 1.17 | 49.9 | 68 | 1 |
160 | 50 | 180 | 10 | 1.05 | 33.1 | 91 | 2 | 1.83 | 45.8 | 107 | 3 |
160 | 70 | 252 | 15 | 1.35 | 31.7 | 117 | 4 | 2.32 | 43 | 135 | 4 |
160 | 95 | 342 | 25 | 1.7 | 30.6 | 147 | 5 | 2.85 | 40.4 | 166 | 6 |
160 | 115 | 414 | 35 | 1.94 | 29.7 | 168 | 7 | 3.23 | 38.8 | 188 | 7 |
200 | 45 | 162 | 5 | 0.97 | 33.6 | 84 | 2 | 1.69 | 46.5 | 98 | 2 |
200 | 80 | 288 | 20 | 1.49 | 31.2 | 129 | 4 | 2.54 | 41.8 | 148 | 5 |
200 | 115 | 414 | 35 | 1.94 | 29.7 | 168 | 7 | 3.23 | 38.8 | 188 | 7 |
200 | 150 | 540 | 55 | 2.29 | 28.4 | 199 | 9 | 3.37 | 36.8 | 223 | 10 |
200 | 180 | 648 | 80 | 2.57 | 27.6 | 223 | 11 | 4.3 | 35.4 | 251 | 12 |
250 | 70 | 252 | 5 | 1.53 | 33.8 | 133 | 1 | 2.67 | 47 | 155 | 1 |
250 | 125 | 450 | 15 | 2.35 | 31.3 | 203 | 2 | 4.14 | 43 | 242 | 3 |
250 | 180 | 648 | 25 | 3.1 | 30 | 269 | 3 | 5.29 | 39.9 | 308 | 4 |
250 | 235 | 846 | 40 | 3.76 | 29 | 326 | 5 | 6.29 | 37.8 | 367 | 5 |
250 | 290 | 1044 | 60 | 4.29 | 28.1 | 372 | 6 | 7.2 | 36.2 | 420 | 7 |
315 | 115 | 414 | 5 | 2.5 | 33.7 | 217 | 1 | 4.41 | 47.2 | 257 | 1 |
315 | 200 | 720 | 15 | 3.82 | 31.5 | 331 | 2 | 6.66 | 43.1 | 388 | 3 |
315 | 285 | 1026 | 25 | 5.02 | 30.4 | 436 | 4 | 8.45 | 40.1 | 493 | 4 |
315 | 375 | 1350 | 40 | 6.05 | 29.1 | 525 | 5 | 10.11 | 37.9 | 589 | 6 |
315 | 460 | 1656 | 60 | 6.89 | 28.2 | 597 | 7 | 11.52 | 36.4 | 672 | 7 |
400 | 185 | 666 | 5 | 4.02 | 33.7 | 348 | 2 | 7.08 | 47.2 | 413 | 2 |
400 | 325 | 1170 | 15 | 6.24 | 31.6 | 542 | 3 | 10.55 | 42.4 | 615 | 4 |
400 | 465 | 1674 | 30 | 8.06 | 30.1 | 699 | 5 | 13.4 | 39.5 | 781 | 6 |
400 | 605 | 2178 | 50 | 9.54 | 28.8 | 827 | 7 | 15.89 | 37.4 | 927 | 8 |
400 | 750 | 2700 | 75 | 10.92 | 27.9 | 947 | 9 | 18.22 | 35.8 | 1062 | 10 |
Φ: Thermal output
PWW: Pumped hot water heating system, flow temperature/return temperature
te: Inlet airflow temperature
ta: Outlet airflow temperature
qv: Volume flow rate
qm: Mass flow rate
Δpv: Water-side differential pressure
Δpst: Static differential pressure
Circular hot water heat exchangers for reheating the airflow in ventilation and air conditioning systems. Dimensions suitable for VAV terminal units TVR and CAV control units RN and VFC. Spigot with lip seal for ducts according to EN 1506 or EN 13180. Casing air leakage according to EN 15727, class D.
Materials and surfaces
Technical data
Sizing data
WL | / | 160 |
---|---|---|
| | | | |
1 | 2 |
Order example: WL/160
Type | WL – Hot water heat exchanger |
Nominal size [mm] | 160 |
Share page
Recommend this page
Recommend this page by sending a link by mail.
Share page
Thank you for your recommendation!
Your recommendation has been sent and should arrive shortly.
Contact
We are here for you
Please specify your message and type of request.
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be
Contact
We are here for you
Please specify your message and type of request.
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be