00133840_0
TNC-SVC04MB (example)
00133840_0

TNC-SVC0*DPR*

Pre-configured modular base station for the rapid implementation and adjustment of control systems

Pre-configured modular base station with power supply units, relays and controllers, for the rapid implementation and adjustment of control systems

  • Space saving, compact design
  • All components are already wired to rail mount terminals
  • Quick, error free assembly and installation
  • Robust design
  • With TROXNETCOM Basic User Software for rapid and safe commissioning and configuration
  • Integral display, also for operation

Application

Application

  • Pre-configured AS-i base stations for controllers with two masters for 62 AS-i participants (TNC-A1306), an AS-i power supply unit TNC-A1256 = 2.8 A or TNC-A1258 = 8 A and switching power supply unit (TNC-D1020), and one or two additional relay modules (TNC-Z0094)
  • Installed and wired to rail mount terminals
  • Plastic casing, free of halogens, with transparent cover
  • With TNC Basic User Software for fire and smoke protection

Technical information

  • Function
  • Technology
  • Specification text
  • Order code
AS-i pre-configured switch boxes TNC 00132580_0

DescriptionTNC-SVC03DP, -04DP, -03DPR, -04DPR, -03DPRR, -04DPRR
Casing dimensions (B × H × T)TNC-SVC03DP, -04DP, -03DPR, -04PDR: 450 × 300 × 210 mm; TNC-SVC03DPRR, -04PDRR: 600 × 300 × 210 mm
Casing materialPlastic, free of halogens, with transparent cover
Wired componentsTNC-SVC03DP: 1 × TNC-A1306; 2 × TNC-A1256, 1 × TNC-D1020; TNC-SVC04DP: 1 × TNC-A1306; 2 × TNC-A1258, 1 × TNC-D1020; TNC-SVC03DPR: 1 × TNC-A1306; 2 × TNC-A1256, 1 × TNC-D1020, 1 × Z0094; TNC-SVC04DPR: 1 × TNC-A1306; 2 × TNC-A1258, 1 × TNC-D1020, 1 × Z0094; TNC-SVC03DPRR: 1 × TNC-A1306; 2 × TNC-A1256, 1 × TNC-D1020, 2 × Z0094; TNC-SVC04DPRR: 1 × TNC-A1306; 2 × TNC-A1258, 1 × TNC-D1020, 2 × Z0094
Mains supply230 V AC, 50 Hz
Max. power consumptionTNC-SVC03DP, -03DPR, -03DPRR: 0,2 KW; TNC-SVC04DP, -04DPR, -04DPRR: 0,5 KW
Pre fuse20 A
Protection levelIP 65


Standard description (characteristics)

Switch box 'Controller and power unit'

  • Dimensions: 450 × 300 × 210 mm (TNC-SVC03DP, -03DPR, -04DP, -04DPR)
  • Dimensions: 600 × 300 × 210 mm (TNC-SVC03DPRR, -04DPRR)
  • Casing materials: Plastic, free of halogens, with transparent cover
  • Components: installed and wired to rail mount terminals
  • Cable glands: M20 with clamping bracket for mains cable, AS-i bus cable and network cable
  • PROFIBUS DP connector
  • European 'Schuko' socket for programming device
  • Circuit breaker: 16 A
  • Mains supply: 230 V AC, 50 Hz
  • Controller: TNC-A1306 PROFIBUS DP with Basic User Software, 2 masters
  • Switching power supply unit: TNC-D1020 = 1.3 A
  • Power supply unit: 2 × TNC-A1256 = 2.8 A (TNC-SVC03DP, -03DPR*, -03DPRR*) or 2 × TNC-A1258 = 8 A (TNC-SVC04DP; -04DPR*, -04DPRR*) (*no. of relay modules)
  • Make: TROX GmbH or equivalent
  • Type: TNC-SVC0*DP*

00224513_0

 Type
TNC-SV       Configured switch cabinet

 Type of base station
R       Repeater
C       Controller
D       Display

 

 Components
       Repeater (R)
01       1×TNC-A2225, 1×TNC-A1256
02       1×TNC-A2225, 1×TNC-A1258
       Controller (C)
01DP       1×TNC-A1305, 1×TNC-A1256, 1×TNC-D1020
02DP       1×TNC-A1305, 1×TNC-A1258, 1×TNC-D1020
03DP       1×TNC-A1306, 2×TNC-A1256, 1×TNC-D1020
04DP       1×TNC-A1306, 2×TNC-A1258, 1×TNC-D1020
01MB       1×TNC-A1353, 1×TNC-A1256, 1×TNC-D1020
02MB       1×TNC-A1353, 1×TNC-A1258, 1×TNC-D1020
03MB       1×TNC-A1354, 2×TNC-A1256, 1×TNC-D1020
04MB       1×TNC-A1354, 2×TNC-A1258, 1×TNC-D1020
       Display (D)
TP043       1×TP043N, 1×TNC-D1030
TP057       1×TP057N, 1×TNC-D1030
TP104       1×TP104N, 1×TNC-D1030
TP121       1×TP121N, 1×TNC-D1030

 Relay module
       For controllers only (C)
       No entry: no relay module
R       1×TNC-Z0094
RR       2×TNC-Z0094

 

Downloads

product information

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request.
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Contact

We are here for you

Please specify your message and type of request.
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be