EASYCONNECT

For the commissioning and diagnosis of EASYLAB components, FSE, and FMS

Software for the configuration and diagnosis of controllers Type TCU3, adapter modules TAM, automatic sash device FSE, and monitoring system FMS

  • Display of actual operating values
  • Interactive navigation
  • Extensive diagnosis and diagram functions
  • Creation of configuration protocols and backup files
  • The software automatically recognises the controller type and displays the corresponding operating values and parameters
  • Selection of dialogue language and of unit of measure for the volume flow rate
  • Connecting cable and USB adapter are included in the supply package


Optional equipment and accessories

  • Bluetooth adapter module BlueCON for wireless communication

Application

Application

  • EasyConnect configuration software for EASYLAB controllers TCU3, adapter modules TAM, and monitoring systems FMS
  • Used to change the configuration of fume cupboard controllers, supply air or extract air controllers, differential pressure controllers, and adapter modules
  • Extensive functions for configuration and commissioning
  • Functions for test and fault diagnosis
  • Documentation of configuration settings

Special characteristics

  • Display of actual operating values
  • Interactive navigation
  • Extensive diagnosis and diagram functions
  • Creation of configuration protocols and backup files
  • Selection of dialogue language and of unit of measure for the volume flow rate
  • Connecting cable and USB adapter are included in the supply package
  • Optional Bluetooth adapter module BlueCON for wireless communication

Description

Variants

  • CAB: Configuration software with connecting cable and USB RS485 (cable connection)
  • BC: Configuration software with Bluetooth adapter module BlueCON (wireless communication)

Parts and characteristics

  • PC software
  • Interface adapter USB 2.0, RS485, including CD with driver software
  • Plug-in cable
  • PC side: 9-pole D-SUB socket; EASYLAB side: RJ45
  • Graphical user interface (Windows-based)
  • Based on the Microsoft.Net Framework (included in the software package)
  • Commissioning wizard to facilitate adjustments to the controller configuration
  • Access to configuration parameters can be restricted (read only)

System requirements

PC or notebook

  • Windows XP with SP3
  • Windows Vista, SP2 or higher
  • Windows 7 32-bit and 64-bit versions
  • USB or Bluetooth interface
  • Screen resolution 800 × 600

Licensing

  • Licence is valid for one computer
  • Licence is linked to the hardware (licence key required)

Technical information

Function, Order code, Related products

  • Function
  • Order code

The software displays values, parameters and functions on a graphical user interface (GUI). The software automatically recognises the controller type and displays the corresponding operating values and parameters

  • Display of actual operating values
  • Display of room operating values on the controller with room management function
  • Commissioning of individual controllers and room controllers (controllers with room management function), with commissioning wizard
  • Diagnosis for all controller connections
  • Graphical display of the most important operating values in a time diagram
  • Backup function to restore the factory or commissioning settings
  • Identification of programme users and hence documentation of configuration changes by user
  • Dialogue language: English or German
  • Unit of measure for volume flow rate: m³/h, l/s or cfm
  • Device configuration is saved in files and can be used to create a project database
  • Documentation of the controller configuration in a PDF protocol file with individual logo and letterhead data

It is possible to define different user groups with limited access to functions (defined by licence code). The software supports several levels of access rights.

  • Display of actual operating values and diagnosis data
  • Display and change of configuration data
  • Change of service interval
  • Backup function

00137356_0

 Software
EasyConnect Configuration software

 

 Interface adapter
CABUSB–RS485 and connnecting cable (cable connection)
BCBluetooth adapter module BlueCON (wireless communication)

 

Installation details

  • Installation details

Installation and commissioning

Prepare computer

  • Install software
  • Connect interface adapter USB-RS485
  • Install driver for USB-RS485 from CD
  • Request licence key and enter licence key
  • Select communication port COMx

Commissioning of EASYLAB

  • Connect EASYLAB controller or adapter module
  • Start software
  • Open configuration or diagnosis window and carry out required actions

Downloads

product information

operation manuals

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request.
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Contact

We are here for you

Please specify your message and type of request.
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be