Eka2-EU
Eka2-EU
EK2-EU smoke control
dampers with ventilation
function for heat and
smoke extraction
EK-JZ smoke control
dampers with ventilation
function for heat and
smoke extraction
EK-JS for mechanical
smoke extract systems,
smoke control damper for
single compartments

EKA2-EU                         

FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDITIONAL SUPPLY AIR INLET

Rectangular smoke control dampers with air extract function, for smoke extraction with mechanical smoke extract systems or as an additional supply air inlet

  • Complies with product standard DIN EN 12101-8 and is classified in accordance with DIN EN 13501-4
  • Classified EI 90/120 (vedw,how i<->o) S 1000/1500 Cmod AA multi
  • Pressure level 2 (-1000 Pa - 500 Pa) and pressure level 3 (-1500 Pa - 500 Pa) depending on usage
  • Can be used in smoke extract systems or in heating and ventilation systems or in a combination of these
  • For systems that require automatic release (AA)
  • Wide range of application options for fire compartment separation
  • Single-blade room partitioning with mechanical resistance
  • Sheet steel construction in lightweight design
  • Silicone free
  • No stop bars, therefore large free cross-section
  • Leakage tightness class at least 3C for casing and damper tightness, in accordance with DIN EN 1751
  • Thermal insulation with insulating wool (optionally, as it depends on the airflow direction)
  • Connection to air ducts in accordance with DIN EN 1366-1 and DIN EN 1366-8 (self-contained duct system or thermally insulated) or tested in accordance with DIN EN 1366-9
  • For smoke extract ducts made of sheet steel or independent smoke extract ducts from 35 mm wall thickness and in air shafts
  • Integration into the management and control equipment with TROXNETCOM or with various control bus systems possible

General information

Application

  • TROX smoke control dampers of Type EKA2-EU, with CE marking and Declaration of Performance, for smoke extraction via mechanical smoke extract systems
  • Provision of outdoor air supply for mechanical smoke extract systems
  • Can be used with ventilation function if the mechanical smoke extract system is approved for ventilation by the building authorities
  • Integration into the management and control equipment with TROXNETCOM


Special characteristics

  • Declaration of Performance according to Construction Products Regulation
  • Complies with the European product standard DIN EN 12101-8
  • Tested for fire resistance properties according to DIN 1366-10 and DIN EN 1366-2
  • Hygiene requirements conform to VDI 6022 part 1, VDI 3803, DIN 1946 part 4 and DIN EN 13779
  • Corrosion protection according to DIN EN 15650 in connection with DIN EN 60068-2-52
  • Closed blade air leakage to DIN EN 1751, class 3
  • Casing air leakage according to DIN EN 1751, class C
  • Low differential pressure and sound power level
  • Any airflow direction
  • Integration into the management and control equipment with TROXNETCOM


Classification

  • EI 90/120 (vew,how i<->o) S 1500 Cmod AA multi
  • EI 90/120 (vedw,how i<->o) S 1000 Cmod AA multi


Nominal sizes

  • W × H: 200 × 200 - 1500 × 800 mm or up to 1250 x 1000 mm (intermediate sizes possible in increments of 1 mm)
  • L: 305 mm or 500 mm


Parts and characteristics

  • The damper casing, including all mechanical components, is made of lightweight steel or sheet steel.
  • The damper blade is made of a special insulating material, optionally also available in an impregnated version.
  • Depending on the ambient temperature, the closed damper blade is sealed with a hot seal or a cold seal to prevent the
  • spread of heat and smoke.
  • The design variants with powder-coated casings meet increased requirements for corrosion protection


Attachments 1

  • Cover grille
  • Cover grille up to nominal width 1500 x 800 mm
  • Extension piece


Anbauteile 2

  • OPEN/CLOSE actuator, with 24 V AC/DC or 230 V AC supply voltage


Technical data

  • Nominal sizes: 200 × 200 - 1500 x 800 or 1250 x 1000 mm
  • Casing lengths: 305 and 500 mm
  • Volume flow rate range: up to 12000 l/s or up to 43200 m³/h at 10 m/s
  • Differential pressure range: pressure level 3: -1500 to 500 Pa
  • Temperature range: at least –30 to 50 °C
  • Upstream velocity: ≤ 15 m/s


Useful additions

  • Duct smoke detector RM-O-3-D
  • Duct smoke detector with airflow monitor RM-O-VS-D
  • Smoke control damper EK-JZ
  • Smoke control damper EK-EU

TROX-TLT smoke exhaust fans from the X-FANS subassembly

  • Smoke exhaust fan for roof installation BVDAX/BVD
  • Smoke exhaust fan for wall installation BVW/BVWAXN
  • Smoke exhaust centrifugal fan BVREH/BVRA
  • Smoke exhaust jet fans BVGAX/BVGAXN

All smoke exhaust fans are tested in accordance with DIN EN 12101-3, for F200/F300/F400 and F600, depending on the type. With CE marking, Declaration of Performance and application approval for the German market.

Standards and guidelines

  • Complies with the European product standard DIN EN 12101-8 Smoke and heat control - Smoke control dampers
  • Is classified according to DIN EN 13501-4 Fire classification of construction products and building elements
  • Fire protection tested in accordance with DIN EN 1366-2 and DIN 1366-10 Fire resistance tests for installations - smoke control dampers
  • DIN EN 1751 Ventilation for buildings – Air terminal devices
  • Hygienic requirements in accordance with VDI 6022 Sheet 1, VDI 3803, DIN 1946 Part 4 and DIN EN 13779
  • Corrosion protection in accordance with DIN EN 15650 in conjunction with DIN EN 60068-2-52


Maintenance

  • Smoke control dampers must be operational at all times and must be maintained regularly so that they meet the performance requirements.
  • Maintenance at least once every six months; maintenance must be recorded; documents must be kept for reference.
  • The owner of the smoke extract system must arrange for a functional check of the smoke control damper every six months. For this purposes, follow the basic maintenance specifications according to DIN EN 13306 in conjunction with DIN 31051. If two consecutive tests at intervals of 6 months do not reveal any functional defects, the smoke control damper only needs to be checked once a year.
  • Depending on the installation location, country-specific regulations may apply.
  • For details on maintenance and inspection, please refer to the installation and operating manual.


Material and surfaces

  • electrogalvanised steel parts
  • galvanised sheet steel
  • Special insulating material (cement-bonded board material)
  • intumescent strips and profiles
  • EPDM profile seal
  • PE foil tape


Equivalence criteria

  • EI 90/120 (vew,how i<->o) S 1500 Cmod AA multi
  • EI 90/120 (vedw,how i<->o) S 1000 Cmod AA multi
  • Fire resistance up to 120 minutes
  • Thermal insulation with insulating wool (optionally, as it depends on the airflow direction)
  • Connection to ducts in accordance with DIN EN 1366-1 and DIN EN 1366-8 (self-contained air duct system or thermally insulated) or tested in accordance with DIN EN 1366-9 Installation in air distributing shafts is possible.
  • no stop bars, therefore large free cross-section
  • single-blade room partitioning with mechanical resistance
  • For smoke extract ducts made of sheet steel, or self contained duct systems with a wall thickness of 35 mm or more
  • Pressure level 2 (-1000 Pa - 500 Pa) and pressure level 3 (-1500 Pa - 500 Pa) depending on usage
  • Smoke-tight with at least leakage class 3 according to DIN EN 1751
  • Silicone free


Information technique

  • FUNCTION
  • TECHNICAL DATA
  • SPECIFICATION TEXT
  • ORDER CODE
Schematic illustration of the EKA2-EU with OPEN/CLOSE actuator Schematische Darstellung EKA2-EU mit AUF/ZU-Stellantrieb

1 Casing 

2 Damper blade 

3 Product label 

4 Actuator

Smoke control dampers are used in mechanical smoke extract systems. They are used for extracting smoke gases and for providing additional supply air to one or more fire compartments. The dampers are made of galvanised sheet steel and are opened by an actuator (with 24V AC/DC or 230V AC supply voltage) in the area where smoke is to be extracted, either when smoke is detected by a duct smoke detector, or activation via a fire alarm system. Smoke control dampers have two safe positions: fully open and fully closed. In the case of fire-resistant smoke control dampers for multiple compartments, the safe position is either 'open' or 'closed', depending on the fire site and the path of the smoke to be extracted. The EKA2-EU can be used in combined systems (combination damper) for ventilation and is suitable for restricting extract air volume flows, provided that the damper blade throttle position is not adjusted while the smoke extraction unit is running. In OPEN position, at least 75% of the free cross-sectional area must be maintained, even in the event of a fire. Regular maintenance of the smoke control damper is required to ensure its functional reliability.

Téléchargements

Information produit

Certificats

Manuels d'utilisation

production {"x-frame-options"=>"SAMEORIGIN", "x-xss-protection"=>"1; mode=block", "x-content-type-options"=>"nosniff", "x-download-options"=>"noopen", "x-permitted-cross-domain-policies"=>"none", "referrer-policy"=>"strict-origin-when-cross-origin", "strict-transport-security"=>"max-age=31536000; includeSubDomains", "content-type"=>"text/html; charset=utf-8"}

Partager la page

Recommander cette page

Recommander cette page en envoyant un lien par mail.

Les champs marqués d'un (*) sont obligatoires.

Partager la page

Merci pour votre recommandation !

Votre recommandation a été envoyée et devrait arriver dans les plus brefs délais.

Contact

Nous sommes à votre disposition

Veuillez préciser votre message et le type de demande
Tel.: +32 (0) 2/522 07 80

Les champs marqués d'un (*) sont obligatoires.

Contact

Merci pour votre message !

Votre message a été envoyé et sera traité dans les plus brefs délais.
Notre département de traitement des demandes prendra contact avec vous dès que possible.
Pour les questions d'ordre général concernant les produits ou services, vous pouvez aussi nous appeler :
Tel.: +32 (0) 2/522 07 80

Contact

Nous sommes à votre disposition

Veuillez préciser votre message et le type de demande
Tel.: +32 (0) 2/522 07 80

Pièce jointe (max. 10MB)

Les champs marqués d'un (*) sont obligatoires.

Contact

Merci pour votre message !

Votre message a été envoyé et sera traité dans les plus brefs délais.
Notre département de traitement des demandes prendra contact avec vous dès que possible.
Pour les questions d'ordre général concernant les produits ou services, vous pouvez aussi nous appeler :
Tel.: +32 (0) 2/522 07 80